X-RAY DIFFRACTION CHARACTERIZATION OF CRYSTALLINITY AND PHASE COMPOSITION IN PLASMA-SPRAYED HYDROXYLAPATITE COATINGS




 CHAPTER I
INTRODUCTION

Medical and dental implants employing hydroxylapatite (HA) plasma-sprayed coatings on a structural substrate are now widely used in reconstructive surgery. Both the crystallinity of the coating and the crystalline phase composition depend upon the plasma spray processing parameters and are believed to affect the biological response to the ceramic coating.[1,2,3,4] To verify the phase composition achieved, x-ray diffraction characterization of the coatings is recommended by the Food and Drug Administration [5] and required in ASTM F1185-88, "Standard Specification for Composition of Ceramic Hydroxylapatite for Surgical Implants".[6]
During the plasma-spray process, highly crystalline sintered HA powder is rapidly heated to a partially molten state and deposited at high velocity on a  relatively cold metallic substrate, commonly the titanium alloy Ti-6Al-4V. Variation in either the plasma-spray conditions, particularly the thermal history, or in the composition of the starting HA powder can alter both the phase composition and crystallinity of the coating. The α or β forms of tricalcium phosphate (TCP), Ca3(PO4)2; and calcium oxide, CaO, have been observed in plasma-sprayed coatings. [1,2,3,4,7]
X-ray diffraction methods have long been applied to characterize HA and related ceramic materials. However, the quantitative phase analysis methods described to date for plasma-sprayed HA coatings have usually been developed to measure specific features of the complex diffraction patterns, such as crystallinity or HA content, rather than providing complete phase analysis. The effects of variation in the mass absorption coefficients of the component phases are not addressed, or require an array of known mixtures for calibration. The crystallinity of biological or precipitated HA can be calculated from the XRD peak-to-background ratio of a mixture consisting of a single crystalline phase mixed with an amorphous fraction relative to that of a fully crystalline reference sample. [8,9] This method is not, however, generally applicable to plasma-sprayed coatings because of the potential presence of multiple phases.
The purpose of this paper is to describe an x-ray diffraction quantitative phase analysis technique applicable to HA plasma-sprayed coatings based uponthe Reference Intensity Ratio (RIR) method commonly applied in mineralogy which provides complete phase analysis [10,11], modified to employ an external rather than an internal standard.

No comments:

Post a Comment